Fire Test Report YUMA VANTEX PVC MEMBRANE DIN 4102‑1:1998‑05VT6-DIN 4102-FR
Report No. AJFS2403002430FF · Date: APR.01, 2024 SGS Ref No. QDHL2403002843SD
| (DIN 4102‑1 |
1998‑05) |
| • "Brandschacht" Test |
PASSED |
| • Ignitability Test |
PASSED |
| • Sample Conditioning |
14 Days at 23±2°C / 50±5% RH |
| • Test Period |
MAR.14, 2024 – MAR.29, 2024 |
Sample Details
| Product Description |
YUMA VANTEX PVC MEMBRANE |
| Color |
White |
| Area Density |
1.3 kg/m² |
| Thickness |
1.0mm |
| Sample Size |
190mm×1000mm, 190mm×90mm, 230mm×90mm |
| Exposed (tested) Surface |
Smooth Surface |
"Brandschacht" Test Results
| Parameter |
Lengthwise |
Widthwise |
| Max. Flame Height |
70 cm |
70 cm |
| Time (min:s) |
03:51 |
03:39 |
| Melting/Burning Through |
Yes (00:30) |
Yes (00:32) |
| Back of Specimen – Flaming/Glowing |
Yes (00:30) |
Yes (00:32) |
| Back of Specimen – Discolouring |
Yes (00:20) |
Yes (00:23) |
| Burning Droplets – Begin (min:s) |
01:11 |
01:04 |
| Residual Length (cm) |
34.8 (avg) |
35.3 (avg) |
| Smoke Temperature – Max. Avg (°C) |
165.2 |
170.9 |
Ignitability Test Results
| Test Type |
Surface Ignition & Edge Ignition |
| Fire Application Time |
15 seconds |
| Flaming Extinguished Before Gauge Mark |
Yes |
| Flaming Reach Gauge Mark Within 20s |
No |
| Afterflame Time (s) |
2–5 seconds |
| Max. Flame Height (cm) |
5–7 cm |
| Molten Dripping |
No |
| Smoke Development |
Slight |
Classification Criteria & Result
| Requirement |
B1 Criteria (DIN 4102‑1:1998) |
| "Brandschacht" – Residual Length |
Mean ≥ 15 cm, no individual < 0 cm |
| "Brandschacht" – Effluent Temperature |
Mean ≤ 200°C |
| Ignitability Test |
Flaming does not reach gauge mark within 20s |
| Final Classification |
✔ PASSED – Class B1 |
Certification & Accreditation
| Test Standard |
DIN 4102‑1:1998‑05 |
| Test Method |
DIN 4102-15:1990, DIN 4102-16:2015 |
| Laboratory |
SGS‑CSTC Standards Technical Services Co., Ltd. |
| Accreditation |
CNAS L4743 |